+31 316 84 44 01 | info@aseckunststoffen.nl
 

 
Filter:
 
Material
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
MaterialCharacteristic property applicationsResinSubstrate
AS EP CC 201Epoxy-laminated cotton cloth, CTI 600, fine weaveEpoxyWoven cotton cloth
AS EP CP 201Epoxy-laminated cellulose paper, UL 94 V-0EpoxyCellulose paper
AS EP PC 301Epoxy-laminated polyester fiber cloth, SF6-resistantEpoxyPolyester fiber
AS EP GC 201Electrical and mechanical applications, TC 130EpoxyWoven glass cloth
AS EP GC 202As type 201 but with combustibility according to UL 94 V-0EpoxyWoven glass cloth
AS EP GC 203As type 201 but with TC 155EpoxyWoven glass cloth
AS EP GC 204As type 203 but with combustibility according to UL 94 V-0EpoxyWoven glass cloth
AS EP GC 205As type 203 but with heavyweight roving as substrateEpoxyWoven glass cloth
AS EP GC 306As type 203 but tracking-resistant, CTI 600EpoxyWoven glass cloth
AS EP GC 307As type 306 but with heavyweight roving as substrate 3EpoxyWoven glass cloth
AS EP GC 308As type 203 but with TC 180EpoxyWoven glass cloth
AS EP GC 309As type 201 but with defined flexural strength at 130 °CEpoxyWoven glass cloth
AS EP GC 310As type 202 but with zero-halogen flame retardant, V-0EpoxyWoven glass cloth
AS EP GC 311As type 204 but with zero-halogen flame retardant, V-0EpoxyWoven glass cloth
AS MF CC 201Resistant to arcs and trackingMelamineWoven cotton cloth
AS MF GC 201Resistant to arcs and trackingMelamineWoven glass cloth
AS PF CP 201Mechanical applicationsPhenolicCellulose paper
AS PF CP 202High-voltage grade for mains frequency in oilPhenolicCellulose paper
AS PF CP 203Electrical applications at normal humidityPhenolicCellulose paper
AS PF CP 204Stable electrical properties at high humidityPhenolicCellulose paper
AS PF CP 205As type 204 but with flame retardant, V-1PhenolicCellulose paper
AS PF CP 206Stable electrical properties at high humidityPhenolicCellulose paper
AS PF CP 207Cold-punching gradePhenolicCellulose paper
AS PF CP 308As type 206 but with flame retardant, V-1PhenolicCellulose paper
AS PF CC 201Mechanical applications, coarse weavePhenolicWoven cotton cloth
AS PF CC 202Mechanical and electrical applications, coarse weavePhenolicWoven cotton cloth
AS PF CC 203Mechanical applications, fine weave PhenolicWoven cotton cloth
AS PF CC 204Mechanical and electrical applications, fine weavePhenolicWoven cotton cloth
AS PF CC 305Mechanical and electrical applications, very fine weavePhenolicWoven cotton cloth
AS PF GC 201Phenolic-laminated glass clothPhenolicWoven glass cloth
Availability
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
AvailabilitySizesThickness
Unitmmmm
AS EP CC 2011050x1020, 1050x2150 and 1250x28000.1-360
AS EP CP 2011050x1020, 1050x2150 and 1250x28000.1-360
AS EP PC 3011050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 2011050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 2021050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 2031050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 2041050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 2051050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3061050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3071050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3081050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3091050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3101050x1020, 1050x2150 and 1250x28000.1-360
AS EP GC 3111050x1020, 1050x2150 and 1250x28000.1-360
AS MF CC 2011050x1020, 1050x2150 and 1250x28000.1-360
AS MF GC 2011050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2011050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2021050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2031050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2041050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2051050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2061050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 2071050x1020, 1050x2150 and 1250x28000.1-360
AS PF CP 3081050x1020, 1050x2150 and 1250x28000.1-360
AS PF CC 2011050x1020, 1050x2150 and 1250x28000.1-360
AS PF CC 2021050x1020, 1050x2150 and 1250x28000.1-360
AS PF CC 2031050x1020, 1050x2150 and 1250x28000.1-360
AS PF CC 2041050x1020, 1050x2150 and 1250x28000.1-360
AS PF CC 3051050x1020, 1050x2150 and 1250x28000.1-360
AS PF GC 2011050x1020, 1050x2150 and 1250x28000.1-360
Physical Properties
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
Physical PropertiesDensityWater absorption (thickness 10 mm)
DIN EN 60893-28.18.2
Test StandardISO 1183ISO 62
Unitg/cm³mg
Min/MaxMax
AS EP CC 2011.2-1.4149
AS EP CP 2011.3-1.4-
AS EP PC 3011.2-1.4220
AS EP GC 2011.8-2.034
AS EP GC 2021.8-2.034
AS EP GC 2031.8-2.034
AS EP GC 2041.8-2.034
AS EP GC 2051.8-2.034
AS EP GC 3061.8-2.034
AS EP GC 3071.8-2.034
AS EP GC 3081.8-2.034
AS EP GC 3091.8-2.034
AS EP GC 3101.8-2.034
AS EP GC 3111.8-2.034
AS MF CC 2011.3-1.5305
AS MF GC 2011.8-2.0414
AS PF CP 2011.3-1.4920
AS PF CP 2021.3-1.4550
AS PF CP 2031.3-1.4320
AS PF CP 2041.3-1.4113
AS PF CP 2051.3-1.4113
AS PF CP 2061.3-1.4149
AS PF CP 2071.3-1.4920
AS PF CP 3081.3-1.4149
AS PF CC 2011.3-1.4319
AS PF CC 2021.3-1.4209
AS PF CC 2031.3-1.4319
AS PF CC 2041.3-1.4209
AS PF CC 3051.3-1.4319
AS PF GC 2011.6-1.8310
Mechanical Properties
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
Mechanical PropertiesFlexural strengthElastic modulus from bending testCompressive strength perpendicularImpact strength Charpy or IzodShear strength parallelTensile strength
DIN EN 60893-25.15.25.35.4.2/5.4.35.55.6
Test StandardISO 178ISO 178ISO 604ISO 179/3CVDE 0318/2ISO 527-4
UnitMPaMPaMPakJ/m²MPaMPa
Min/MaxMinMinMinMinMinMin
AS EP CC 2011356.00023061010
AS EP CP 2011106.0001600080
AS EP PC 3011403.0002005512135
AS EP GC 20134022.0003504230300
AS EP GC 20234022.0003504230300
AS EP GC 203340 ⁽¹⁾22.0003505030300
AS EP GC 204341 ⁽¹⁾22.0003505030300
AS EP GC 205342 ⁽¹⁾24.0003507020300
AS EP GC 306343 ⁽¹⁾22.0003505030300
AS EP GC 307344 ⁽¹⁾24.0003507020300
AS EP GC 308345 ⁽¹⁾22.0003505030300
AS EP GC 309346 ⁽¹⁾22.0003504230300
AS EP GC 310347 ⁽²⁾22.0003504230300
AS EP GC 311348 ⁽²⁾22.0003505030300
AS MF CC 201349 ⁽¹⁾5.000903860
AS MF GC 201350 ⁽¹⁾14.0002753512150
AS PF CP 2011357.000300-10120
AS PF CP 2021207.000300-10100
AS PF CP 2031207.000250-10100
AS PF CP 204757.000250-2070
AS PF CP 205755.000250-2060
AS PF CP 206857.000250-2070
AS PF CP 207807.000300-10100
AS PF CP 308857.000250-2070
AS PF CC 2011007.000-82580
AS PF CC 202907.000-72060
AS PF CC 2031107.000-72585
AS PF CC 2041007.000-62080
AS PF CC 3051257.000-62080
AS PF GC 20114014.000-30-100
Electrical Properties
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
Electrical PropertiesDielectric strength perpendic at 90 ºC in oil (thickness 3 mm)Dielectric strength parallel at 90 ºC in oilPermittivity 50 HzPermittivity 1 MHzDissipation factor 50 HzDissipation factor 1 MHzInsulation resistanceProof tracking indexComparative tracking index
DIN EN 60893-26.1.3.16.1.3.16.26.26.26.36.46.46.4
Test StandardIEC 60243-1IEC 60243-1IEC 60250IEC 60250IEC 60250IEC 60250IEC 60167IEC 60112IEC 60112
UnitkV/mmkVMΩVV
Min/MaxMinMinMaxMaxMaxMaxMinMinMin
AS EP CC 2015355.35.30.040.041.000-600
AS EP CP 2011335550.050.0510.000-100
AS EP PC 30110.2455.35.30.050.05100-380
AS EP GC 20110.2455.55.50.040.0450.000-200
AS EP GC 20210.2455.55.50.040.0450.000-200
AS EP GC 20310.2455.55.50.040.0450.000-180
AS EP GC 20410.2455.55.50.040.0450.000-180
AS EP GC 2059455.55.50.040.0410.000-180
AS EP GC 30610.2455.55.50.040.0450.000500600
AS EP GC 3079455.55.50.040.0410.000500600
AS EP GC 30810.2455.55.50.040.0450.000-180
AS EP GC 30910.2455.55.50.040.0450.000-200
AS EP GC 31010.2455.55.50.040.0450.000-200
AS EP GC 31110.2455.55.50.040.0450.000-180
AS MF CC 201415880.030.0310500500
AS MF GC 2015157.57.50.020.02100500500
AS PF CP 201--------100
AS PF CP 2021360 ⁽³⁾-5.5-0.05--100
AS PF CP 2038.415-5.5-0.0550-100
AS PF CP 2048.425-5.5-0.0510.000-100
AS PF CP 2058.420-5.5-0.051.000-100
AS PF CP 2067.725-6-0.051.000-100
AS PF CP 207--------100
AS PF CP 3087.725-6-0.051.000-100
AS PF CC 2010.51----1-100
AS PF CC 2023205.5---50-100
AS PF CC 2030.51----1-100
AS PF CC 2044205.5---50-100
AS PF CC 3050.891----1-100
AS PF GC 2015.7205---100-100
Thermal Properties
 
Datasheet pdf available.
Datasheet pdf not available.
 
Standard types according to DIN EN 60893.
 
Sheets made from industrial laminated materials.
 
Value: Minimum requirements of DIN EN 60893.
Value: Typical values, general recommended values, which must not be used as standard values.
 
(1): The flexural strength measured at 150 ºC ± 3K must not be less than 50% of the defined value.
(2): The flexural strength measured at 130 ºC ± 3K must not be less than 50% of the defined value.
(3): After 96 h pretreatment in air at 105 ºC ± 5K directly prior to testing and immediate immersion in the hot oil.
(4): UL- listed file E307596.
 
Thermal PropertiesThermal enduranceFlammability
DIN EN 60893-27.17.2
Test StandardIEC 60216IEC 60707
UnitT.I.Category
Min/MaxMin
AS EP CC 201130-
AS EP CP 201110V-0
AS EP PC 301130-
AS EP GC 201130-
AS EP GC 202130V-0 ⁽⁴⁾
AS EP GC 203155-
AS EP GC 204155V-0
AS EP GC 205155-
AS EP GC 306155-
AS EP GC 307155-
AS EP GC 308180-
AS EP GC 309130-
AS EP GC 310130V-0
AS EP GC 311155V-0
AS MF CC 201130V-0
AS MF GC 201130V-0
AS PF CP 201120-
AS PF CP 202120-
AS PF CP 203105-
AS PF CP 204105-
AS PF CP 205100V-1
AS PF CP 206105-
AS PF CP 207105-
AS PF CP 308100V-1
AS PF CC 201120-
AS PF CC 202120-
AS PF CC 203120-
AS PF CC 204120-
AS PF CC 305120-
AS PF GC 201120-
 

The above values are provided for general purposes only and not meant to be a specific recommendation for any individual application. All values were determined under laboratory conditions. ASEC Kunststoffen B.V. is not directly neither indirectly responsible for any claim resulting from the use of any information provided in above values. ASEC Kunststoffen B.V. 2016 ©.